Glass Filter Holders for Vacuum Filtration
For small-volume contamination or biological analysisThe glass microanalysis filter holder is designed for vacuum filtration of small- volume liquid samples for particulate or biological contamination analysis.
Features & Benefits
Volume graduations clearly indicate sample volume
Filter support available in fritted glass or stainless steel
Applications
Contamination Analysis (not for use with thick pre-filters or flammable liquids)
XX1002500 | Microanalysis Filter Holder, 25 mm, fritted glass support-1/Pack
XX1002530 | Microanalysis Filter Holder, 25 mm, stainless steel support-1/Pack
XX1002502 | Fritted Glass Base with stopper, 25 mm-1/Pack
XX1002503 | Spring Clamp, 25 mm, aluminum-1/Pack
XX1002508 | No. 5 perforated stopper, sile-5/Pack
XX1002514 | Funnel,15 mL, borosilcate glass-1/Pack
XX1002532 | Base stopper & stainless steel screen-1/Pack
XX1002535 | Gaskets, PTFE coated-10/Pack
XX5002501 | Support Screen, 25 mm, stainless steel-1/Pack
WP6210060 | High Output Pump, 100 V/50–60 Hz-1/Pack
WP6211560 | High Output Pump, 115 V/60 Hz-1/Pack
WP6222050 | High Output Pump, 220 V/50 Hz-1/Pack
XX1002505 | Vacuum filtering flask, 125 mL-1/Pack
XX7100004 | Tubing, 3/16 in. ID x 140 cm, sile-1/Pack
For filtration of corrosive liquids and solventsThe All-Glass Filter Holder was designed Features & Benefits for the filtration of aqueous and organic or corrosive liquids for particulate contamination analysis. The holder can also be used for HPLC solvent preparation. The vacuum connection is integrated into the filter holder base and flask cap, above the filtrate exit level. With this design, you can avoid unintentionally drawing filtrate into vacuum tubing. This design also allows simple transfer of filtrate (i.e., HPLC solvents) by pouring from the receiver flask.
Features and Benefits
All glass construction has broad chemical compatibility
Borosilicate glass parts contact liquid with ground-glass sealing surfaces
Vacuum connection to flask simplifies transfer of filtrate
Applications
Particle Contamination Analysis, HPLC Solvent Filtration, General Filtration and Clarification
XX1504700 | All-Glass Filter Holder Assembly with funnel, fritted base, cap, clamp, 47 mm
XX1004703 | Spring clamp, 47 mm, aluminum
XX1004704 | Glass funnel, 300 mL, borosilcate
XX1504702 | Glass Base & Cap, 47 mm
XX1504705 | Ground Joint Flask, 1 L
XX1504732 | Glass Base & Cap with stainless steel screen, 47 mm
XX2004703 | Gasket, PTFE
XX2004708 | Support screen, 47 mm, stainless steel
XX1004707 | 1L Funnel, 47 mm, ground glass seal
XX2504754 | Funnel Cover, 47mm, sile
XX6200006P | Filter forceps, blunt end, stainless steel
XX7100004 | Tubing, 3/16 in. ID x 140 cm, sile
For 47 mm disc filtersThe Classic Glass Filter Holder is an essential tool for every research lab. The holder’s multipurpose design is appropriate for a variety of applications and is available in three different support materials for compatibility with your specific application needs.
Features & Benefits
Designed for easy loading and removal of membranes
Three membrane support material options to suit a variety of applications
UV sterilize or autoclave with in place for bacteriological analysis
Applications
General Clarification, Bacteriological Analysis, Particulate Contamination Analysis of Oils and Hydraulic Fluids, Exfoliative Cytology
XX1004700 | Glass filter holder assembly with funnel, fritted base, stopper, clamp, 47 mm
XX1004720 | Glass filter holder assembly, PTFE-coated, with funnel, base, stopper clamp, 47 mm
XX1004730 | Glass filter holder with stainless steel screen, 47 mm
XX1004702 | Base for 47 mm glass/filter holder
XX1004703 | Spring clamp, 47 mm, aluminum
XX1004704 | Glass funnel, 300 mL, borosilcate
XX1004708 | No. 8 perforated stopper, sile
XX1004703 | Spring clamp, 47 mm, aluminum
XX1004708 | No. 8 perforated stopper, sile
XX1004722 | Glass base, PTFE-faced, 47 mm
XX1004724 | Funnel, PTFE-faced, 300 mL
XX1004703 | Spring clamp, 47 mm, aluminum
XX1004704 | Glass funnel, 300 mL, borosilcate
XX1004708 | No. 8 perforated stopper, sile
XX1004732 | Glass base with screen, 47 mm
XX1004733 | Glass base without screen, 47 mm
XX2004703 | Gasket, PTFE
XX2004708 | Support screen, 47 mm, stainless steel
WP6210060 | High Output Pump, 100 V/50–60 Hz
WP6211560 | High Output Pump, 115 V/60 Hz
WP6222050 | High Output Pump, 220 V/50 Hz
XX1004705 | Vacuum filtering flask, 1 L
XX1004707 | 1L Funnel, 47 mm, ground glass seal
XX1004744 | Vacuum filtering flask, 4 L
XX7100004 | Tubing, 3/16 in. ID x 140 cm, sile
Bottle-to-bottle filtration of solvents and buffersThe MilliSolve Kit has been designed for the filtration of liquid chromatography buffers and solvents under vacuum. The system uses a 0.45 µm membrane filter to eliminate particles which can shorten column life. Vacuum filtration with the MilliSolve™ system also removes a large portion of dissolved gases from buffers, reducing the risk of air bubbles interfering with LC instruments. With automatic and continuous filtration, there is no need to add liquid into a funnel as filtration progresses. Filtration occurs in a closed system, which is important when filtering hazardous fluids. If open funnel filtration is required, the 300 mL funnel replaces the vacuum cover.
Features & Benefits
Automatic continuous solvent and buffer filtration eliminates the need to pour during filtration.
2L receiving flask includes plug and tubing for storage, eliminating filtered buffer transfer, reducing labor and lessening contamination risk
Conical 2L flask bottom allows access to all filtered solvent or buffer
Applications
Mobile Phase Preparation, Buffer Filtration
XX1604700 | MilliSolve Kit, complete with 2L flask
XX1604700 | MilliSolve Kit, complete with 2L flask
XT1200000 | Tubing for solvent/buffer, PTFE, 70 cm
XX1004703 | Spring clamp, 47 mm, aluminum
XX1004704 | Glass funnel, 300 mL, borosilcate
XX1004704 | Glass funnel, 300 mL, borosilcate
XX1504702 | Glass Base & Cap, 47 mm
XX1504702 | Glass Base & Cap, 47 mm
XX1604701 | Vacuum Cover, ground glass
XX1604701 | Vacuum Cover, ground glass
XX1604705 | Vacuum Flask, 2 L
XX1604705 | Vacuum Flask, 2 L
XX1604705 | Vacuum Flask, 2 L
XX1604705 | Vacuum Flask, 2 L
FHUP04700 | Fluoropore Membrane Filter, PTFE, hydrophobic, unlaminated, 0.5 µm, 47 mm, white, plain
FHUP04700 | Fluoropore Membrane Filter, PTFE, hydrophobic, unlaminated, 0.5 µm, 47 mm, white, plain
HVLP04700 | Durapore Membrane Filter, PVDF, hydrophilic, 0.45 µm, 47 mm, white, plain
HVLP04700 | Durapore Membrane Filter, PVDF, hydrophilic, 0.45 µm, 47 mm, white, plain
XX1504705 | Ground Joint Flask, 1 L
XX1504705 | Ground Joint Flask, 1 L
XX1504732 | Glass Base & Cap with stainless steel screen, 47 mm
XX1504732 | Glass Base & Cap with stainless steel screen, 47 mm
XX1604706 | Vacuum Flask, 5 L, with conical bottom, glass
XX1604706 | Vacuum Flask, 5 L, with conical bottom, glass
XX7100004 | Tubing, 3/16 in. ID x 140 cm, silicone
For bacteriological analysis by epifluorescenceDesigned for accurate, quantitative vacuum filtration of samples for bacteriological analysis by epifluorescence microscopy, the highly polished stainless steel funnel prevents bacterial cells from adhering to surface.
Applications
Bacteriological Analysis by Epifluorescence Microscopy
XF3001200 | Epifluorescence Filter Holder, 13 mm, stainless steel
WP6210060 | High Output Pump, 100 V/50–60 Hz
WP6211560 | High Output Pump, 115 V/60 Hz
WP6222050 | High Output Pump, 220 V/50 Hz
XX1004705 | Vacuum filtering flask, 1 L
XX7100004 | Tubing, 3/16 in. ID x 140 cm, sile
For contamination analysisThe analytical stainless steel filter holders are designed for the vacuum filtration of samples for bacteriological or particulate contamination analysis.
Features & Benefits
Available in three diameters with four available funnel sizes to accommodate samples up to 250 mL
Holder with 250 mL funnel is equipped with a funnel lid, which can be vented using accessory filter unit
Can be autoclaved or flame sterilized
Applications
Bacteriological or Particulate Contamination Analysis
XF2004710 | 100 mL Filter Holder, 47 mm, stainless steel-1/Pack
XF2004725 | 250 mL Filter Holder, 47 mm, stainless steel-1/Pack
XX1002540 | 50 mL Filter Holder, 25 mm, stainless steel-1/Pack
XX1002503 | Spring Clamp, 25 mm, aluminum-1/Pack
XX1002535 | Gaskets, PTFE coated-10/Pack
XX1002542 | Base Assembly for 25 mm filter holder-1/Pack
XX2004718 | No. 8 stopper, 9.5 mm (3/8 in.) hole, sile-5/Pack
XX5002501 | Support Screen, 25 mm, stainless steel-1/Pack
XF2004755 | Stainless Steel Funnel, 100 mL-1/Pack
XF2004756 | Stainless Steel Funnel, 250 mL-1/Pack
XF2004758 | Stainless Steel Support Frit-1/Pack
XX1004703 | Spring clamp, 47 mm, aluminum-1/Pack
XX1004708 | No. 8 perforated stopper, sile-5/Pack
SLFG02550 | Millex-FG Filter Unit, 0.20 µm, hydrophobic PTFE, 25 mm-50/Pack
XX1004705 | Vacuum filtering flask, 1 L-1/Pack
XX1004744 | Vaccum filtering flask, 4 L-1/Pack
XX7100004 | Tubing, 3/16 in. ID x 140 cm, sile-1/Pack
For analysis of flammable liquidsThe Hydrosol filter holder is designed for the filtration of flammable liquids. Unlike other filter holders, the Hydrosol filter holder includes a grounding unit to prevent sparking from static discharge, which can be a safety hazard.
Applications
Vacuum Filtration of Flammable Liquids
XX2004720 | Hydrosol 47 mm filter holder, stainless steel
XX2004702 | Base with screen, gasket and stopper
XX2004703 | Gasket, PTFE
XX2004704 | Funnel & locking ring assembly, stainless steel
XX2004708 | Support screen, 47 mm, stainless steel
XX2004718 | No. 8 stopper, 9.5 mm (3/8 in.) hole, sile
XX20047RK | Replacement parts kit, Hydrosol holder
WP6210060 | High Output Pump, 100 V/50–60 Hz
WP6211560 | High Output Pump, 115 V/60 Hz
WP6222050 | High Output Pump, 220 V/50 Hz
XX1004705 | Vacuum filtering flask, 1 L
XX1004744 | Vacuum filtering flask, 4 L
XX2504700 | 6-place manifold, 47mm, stainless steel
XX2504735 | 3-place manifold, 47mm, stainless steel
XX2604735 | 3-place manifold, 47mm, PVC
XX6200006P | Filter forceps, blunt end, stainless steel
XX7100004 | Tubing, 3/16 in. ID x 140 cm, sile
Reusable, syringe-driven filter unitMake your own syringe filter! Microsyringe and Swinny filter holders give you the flexibility to select the membrane type and diameter that are most appropriate for your application. For sterile filtration, autoclave your holder with the membranes in place. Ultraclean or sterilize small volumes of liquids dispensed by a syringe or install in-line to filter larger volumes.
Features & Benefits
Available in two sizes for a range of process volumes
Durable stainless steel construction ensures years of use, decreasing waste from disposable syringe filters.
Autoclavable with filter in place for sterile filtration
Applications
Ultracleaning or Sterilization of Liquids
XX3001200 | Swinny Filter Holder 13 mm, stainless steel
XX3002500 | Microsyringe Filter Holder 25 mm, Luer-Lok, stainless steel
XX3002514 | Microsyringe Filter Holder 25 mm, NPTF, stainless steel
For in-line High Pressure Filtration, up to 700 barThe In-Line Stainless Steel Filter Holders are designed for filtration of gases or liquids at inlet pressures of 20 to 700 bar. Differential pressure depends on the filter type used. All filter holders maybe autoclaved. The 47 mm In-Line filter holder (cat. no. XX4404700) is equipped with a back-pressure support screen. It maybe autoclaved with filter in place, as long as the optional PTFE-coated support screens (cat. no. XX4404702 and XX4404704) are used. The 47 mm High-Pressure holder (cat. no. XX4504700) may be equipped with the upstream support screen (cat. no. XX4504704) for back-pressure protection of filter.
Features & Benefits
Safe for use with inlet pressures up to 700 bar
Devices are autoclavable; autoclaving with filter in place requires optional PTFE-coated support screens
Applications
In-Line Filtration of Fluid Process Streams
XX4404700 | Filter Holder, 47 mm, stainless steel-1/Pack
XX4404700 | Filter Holder, 47 mm, stainless steel-1/Pack
XX4502500 | HP Filter Holder, 25 mm, stainless steel-1/Pack
XX4502500 | HP Filter Holder, 25 mm, stainless steel-1/Pack
XX4504700 | HP Filter Holder, 47 mm, stainless steel-1/Pack
XX4504700 | HP Filter Holder, 47 mm, stainless steel-1/Pack
XX4504700 | HP Filter Holder, 47 mm, stainless steel-1/Pack
XX45025RK | Replacement Parts Kit, 25 mm filter holder-1/Pack
XX45025RK | Replacement Parts Kit, 25 mm filter holder-1/Pack
009507P | Pipe Plug, 1/8 in.-1/Pack
5614 | Underdrain Screen, 47 mm-1/Pack
XX4204709 | Support Screen, 47 mm-1/Pack
XX4204709 | Support Screen, 47 mm-1/Pack
XX4304701 | O-ring (2-131), silicone-6/Pack
XX4304701 | O-ring (2-131), silicone-6/Pack
XX4404703 | Back-pressure Screen, 47 mm, stainless steel-1/Pack
XX4404703 | Back-pressure Screen, 47 mm, stainless steel-1/Pack
Catalog No- For XX45 047 00-Pack Size
XX4504704 | Filter Support Screen, 47 mm, stainless steel-1/Pack
XX4504704 | Filter Support Screen, 47 mm, stainless steel-1/Pack
XX4504705 | Inner O-ring, 47 mm, PTFE-treated fluoroelastomer-5/Pack
XX4504705 | Inner O-ring, 47 mm, PTFE-treated fluoroelastomer-5/Pack
XX4504710 | Inner O-ring, 47 mm, PTFE-5/Pack
XX4504710 | Inner O-ring, 47 mm, PTFE-5/Pack
XX4504713 | Outer O-ring, 47 mm, fluoroelastomer-10/Pack
XX4504713 | Outer O-ring, 47 mm, fluoroelastomer-10/Pack
XX45047RK | Replacement Parts Kit, 47 mm filter holder-1/Pack
XX45047RK | Replacement Parts Kit, 47 mm filter holder-1/Pack
XX45047RK | Replacement Parts Kit, 47 mm filter holder-1/Pack
Point-of-use, hand-operated solvent filtrationUltra-clean and dispense small volumes of solvent by squeeze-bottle action. This hand pressure operated dispenser features a filter holder fitted with a delivery tube. Used to direct filtered solvent against surfaces.
Features & Benefits
Integrated hand pump eliminates the need for external pump
Holds up to1 L of solvent
Applications
Solvent Filtration Prior to Contamination, Analysis, Solvent Rinsing of Machined Parts and Collection Containers
XX6602500 | Solvent Filtering Dispenser, 25 mm-1/Pack
XX3002502 | Filter Holder Gasket, PTFE-10/Pack
XX3002510 | Filter Holder Support Screen, stainless steel-1/Pack
XX6602501 | Flask and neoprene stopper-1/Pack
Point-of-use solvent filtrationApply a concentrated jet spray of ultra cleaned solvent or rinse solution to surfaces that require washing. Just connect the Filterjet™ dispenser to a dispensing pressure vessel to ensure that the solvent or other liquid is filtered immediately before dispensing. The filter holder (cat. No. XX4002500), which is part of the dispenser, can also be used by itself for in-line pressure filtration of gases
Applications
Solvent Filtration Prior to Contamination Analysis, Solvent Rinsing of Machined Parts and Collection Containers
XX6702500 | Filterjet Solvent Dispenser, 25 mm-1/Pack
XX4002500 | Gas Line Filter Holder, 25 mm, stainless steel-1/Pack
XX40025RK | Replacement Parts Kit for filter holder includes (5) PTFE locking nut washers, (5) PTFE O-rings, (5) stainless steel support screens-1/Pack
XX6702501 | Handle and Valve Assembly-1/Pack
XX6702502 | Valve Seals, PTFE-4/Pack
XX6702506 | Pressure Tubing with 1/4 in. NPT adapters, PE-1/Pack
XX6702507 | Tube Adapter, 1/4 in. NPTM to 1/4 in. Tube-1/Pack
XX6702508 | Tubing, 6 mm O.D. x 3 m, polypropylene-1/Pack
XX67025RK | Replacement Kit for Filterjet Solvent Dispenser includes (1) stainless steel jet nozzle, (1) fan spray nozzle, (1) cone spray nozzle-1/Pack
XX6700030 | Quick-release Nipple & Coupling, 1/4 in. NPTM
XX6700P05 | Dispensing Pressure Vessel, 5 L
YY1301015 | Pressure Gauge, 0–7 bar
YY2029348 | Ball Valve, 1/4 in. NPTF, stainless steel
Pressure-driven filtration of up to 340 mL of liquidThese filter holders are ideal for ultracleaning or sterilizing batch volumes of liquids. The cylindrical barrel holds 100 mL (or 340 mL) of liquid, which is filtered by externally applied gas pressure through a suitable filter supported on the holder base.
Features & Benefits
Filter holder has reservoir to hold 100 mL (or 340 mL) of liquid for batch filtration
Autoclavable with membrane in place for sterile filtration
Applications
Batch Filtration
XX4004700 | Stainless Steel Pressure Filter Holder, 47 mm, 100 mL-1/Pack
XX4004740 | Stainless Steel Pressure Filter Holder, 47 mm, 340 mL-1/Pack
205 | Top Cap with hose adapter-1/Pack
XX2004703 | Gasket, PTFE-25/Pack
XX2004718 | No. 8 stopper, 9.5 mm (3/8 in.) hole, silicone-5/Pack
XX4004704 | Filter Support Screen, stainless steel, 47 mm-1/Pack
XX4004714 | Locking Ring Gasket, PTFE-5/Pack
XX4004716 | O-rings, PTFE-5/Pack
XX40047RK | Replacement Parts Kit, 47 mm holder-1/Pack
XX1004705 | Vacuum filtering flask, 1 L-1/Pack
XX1004744 | Vaccum filtering flask, 4 L-1/Pack
XX6700034 | 3 meters PVC tubing with 9.5 mm internal diameter-1/Pack
XX7100004 | Tubing, 3/16 in. ID x 140 cm, silicone-1/Pack
Filter holders supported by legsThe stainless steel filter holders are designed to ultraclean or sterilize liquids or gases by pressure filtration. PTFE-faced support screens permit autoclaving with membranes in place
YY3009000 | Filter Holder 90 mm, stainless steel-1/Pack
YY3014236 | Filter Holder 142 mm, stainless steel-1/Pack
XX2504705 | Hose adapter, 1/4in. NPTM to 3/8in. ID-1/Pack
XX4204708 | Vent/Relief Valve-1/Pack
YY2209058 | Underdrain Support, 90 mm-1/Pack
YY2209059 | Legs (3)-3/Pack
YY3009053 | O-rings, 90 mm filter housing, PTFE-4/Pack
YY3009054 | Support Screen, PTFE-coated-1/Pack
YY2004045 | Clamp 1 1/2 in. TC-1/Pack
YY2004055 | 1 1/2 in. TC silicone gasket-1/Pack
YY2004076 | Adapter 1-1/2 in. TC to 14 mm-1/Pack
YY2214251 | Legs with Caps, 3/16 in. wrench-3/Pack
YY2214252 | Handwheel Wrench for 142 mm holder-1/Pack
YY2214253 | O-ring, 2-251, PTFE-1/Pack
YY2214257 | Hand Knob-1/Pack
YY2214258 | Underdrain Support, 142 mm - 1/Pack
YY2214265 | O-ring, 2-251, silicone-4/Pack
YY3014234 | Support Screen for 142 mm filter holder, PTFE-coated-1/Pack
YY3029307 | Inlet Flow Deflector, 316 Holder-1/Pack
YY3029366 | Vent/Relief Valve, 9 bar (125 psig)-1/Pack
For multi-sample vacuum filtrationSimultaneously vacuum filter 12 samples for rapid analysis of retentate or filtrate. Numbered positions on the filter plate assure accurate sample tracking. Sealing stoppers maintain vacuum on unused sample cups. Accessory extension barrels increase sample volumes from 15 to 50 mL.
Applications
General Filtration of 15 to 50 mL Samples, Preparation for Scintillation Counting
XX2702550 | 1225 Sampling Manifold - 1/Pack
5162 | Top Plate - 1/Pack
5163 | Support Plate - 1/Pack
XX11000PP | Ball Valve, glass - filled polypropylene - 1/Pack
XX2504755 | Tubing, 1/4in. x 23in., latex - 1/Pack
XX2702509 | Filter O - ring, sile - 30/Pack
XX2702510 | Support Screen, 25 mm, polypropylene - 30/Pack
YY2214257 | Hand Knob - 1/Pack
XX2702552 | Chamber O - rings and plug set - 1/Pack
XX2702555 | Sample Cup Extension Barrel - 12/Pack
XX6200006P | Filter forceps, blunt end, stainless steel - 3/Pack
XX7100004 | Tubing, 3/16 in. ID x 140 cm, sile - 1/Pack
Reusable, autoclavable device with removable membraneThe Sterifil aseptic system was designed as a tool for general filtration applications and filtration of samples for particulate or biological contamination analysis. Sterifil holder and funnel are available separately (without receiver flask and cover) to use with standard 1 L filter flasks or multiple place manifolds.
Features & Benefits
Closed unit protects samples and from environmental contamination
Device is autoclavable with membrane in place for sterile applications with less waste
Optional hand pump allows for on-site filtration
Applications
General Filtration, Field-based Filtration (with optional hand pump), Sterile Filtration, Bioburden Monitoring, Counting Microorganisms, Filtration Processes Requiring Membrane to be Retained
XX1104700 | Sterifil aseptic system, 47 mm - 1/Pack
XX1104710 | Sterifil holder, 250 mL, includes components (1) to (9) - 1/Pack
XX11J4750 | Sterifil holder, 500 mL - 1/Pack
AP2501300 | Glass Fiber Filter with binder, AP25, 13 mm - 100/Pack
SX0001300 | Swinnex Filter Holder, 13 mm - 10/Pack
XX1104702 | Filter holder base and support screen - 1/Pack
XX1104703 | Sterifil funnel cover - 1/Pack
XX1104704 | Sterifil funnel, 250 mL, 47 mm, Polysulfone - 1/Pack
XX1104705 | Sterifil receiver flask, 250 mL - 1/Pack
XX1104706 | Cover for Sterifil receiver flask - 1/Pack
XX1104707 | O - ring, (5 - 329) for Swinnex 47 mm filter holder, sile - 10/Pack
XX1104711 | Caps, gum rubber - 100/Pack
XX1104715 | Support screen, 47 mm, polypropylene - 1/Pack
XX2004718 | No. 8 stopper, 9.5 mm (3/8 in.) hole, sile - 5/Pack
WP6210060 | High Output Pump, 100 V/50–60 Hz - 1/Pack
WP6211560 | High Output Pump, 115 V/60 Hz - 1/Pack
WP6222050 | High Output Pump, 220 V/50 Hz - 1/Pack
XKEM00107 | Hand Vacuum Pump, polypropylene - 1/Pack
XX2604735 | 3 place manifold, 47mm, PVC - 1/Pack
XX7100004 | Tubing, 3/16 in. ID x 140 cm, sile - 1/Pack
Reusable, syringe-driven filter unitMake your own syringe filter! Swinnex® filter holders give you the flexibility to select the membrane type and diameter that are most appropriate for your application. For sterile filtration autoclave your Swinnex® filter holders with the membrane in place. Ultraclean or sterilize small volumes of liquids dispensed by a syringe or install in-line to larger volumes.
Features & Benefits
Available in three sizes for a range of process volumes
Autoclavable with filter in place for sterile filtration
Applications
Ultracleaning or Sterilization of Liquids
SX0001300 | Swinnex Filter Holder, 13 mm - 10/Pack
SX0002500 | Swinnex Filter Holder, 25 mm - 12/Pack
SX0004700 | Swinnex Filter Holder, 47 mm - 8/Pack
SX0001301 | Silicone Gaskets for 13 mm Swinnex filter holder - 100/Pack
SX0002501 | Silicone Gaskets for 25 mm Swinnex filter holder - 100/Pack
SX0004701 | Base O-ring for Swinnex 47 mm filter holder, silicone - 5/Pack
SX00047RK | Replacement parts kit for Swinnex 47 mm filter holder - 1/Pack
XX1104707 | O-ring, (5-329) for Swinnex 47 mm filter holder, silicone - 10/Pack
XX1104715 | Support screen, 47 mm, polypropylene - 1/Pack
XX2702510 | Support Screen, 25 mm, polypropylene - 30/Pack
XX1102012 | Plastic Syringes, 20mL Luer slip, polypropylene - 12/Pack
XX1102503 | Adapter, male M Luer-Lok, nylon - 4/Pack
XX1105005 | Plastic Syringes, 50mL Luer slip, polypropylene - 5/Pack
XX2004718 | No. 8 stopper, 9.5 mm (3/8 in.) hole, silicone - 5/Pack
XX3002568 | Adapter, 1/4 in. NPTF to F Luer-Lok - 1/Pack
XX6200006P | Filter forceps, blunt end, stainless steel - 3/Pack
Reusable pressure-driven filter housingIn line filter holder is used to Ultraclean liquids or gases in line by pressure filtration. Simply open the housing to change the filter without disturbing the attached plumbing.
Features & Benefits
Stepped hose barb connections at both ends for easy installation
Large, easy to grip hand knobs
Applications
General Filtration (in-line)
XX4304700 | In-Line Filter Holder 47 mm - 1/Pack
XX1104715 | Support screen, 47 mm, polypropylene - 1/Pack
XX4304701 | O-ring (2-131), silicone - 6/Pack
XX4304704 | Hose adapter, 1/4 in. NPTF to 5/16 in. ID, polypropylene 2/Pack
XX4304705 | Hand Knobs - 3/Pack
XX4304702 | O-ring, (2-131), fluoroelastomer - 6/Pack
XX4304707 | Stainless Steel Support Screen, 47 mm - 1/Pack
XX6200006P | Filter forceps, blunt end, stainless steel - 3/Pack
XX6700034 | 3 meters PVC tubing with 9.5 mm internal diameter - 1 /Pack