ZHE Hazardous Waste Filtration System (90 mm)
EPA-approved for EP Toxicity Test and TCLP
Do your waste samples contain volatile substances, such as isopropanol, acetone or xylene? Then use our ZHE (Zero Head Space Extractor) Hazardous Waste Filtration system, which is approved by the US Environmental Protection Agency (EPA) as an apparatus for Toxicity Characteristic Leaching Procedure (TCLP) measurement.
Features & Benefits
Allows for pressurization of filter without introducing air, due to movable piston design Prevents loss of volatiles
Manual and automatic venting modes
System cannot be pressurized unless completely assembled, thereby preventing “shooting the piston” out of the unit accidentally
Applications
US EPA Extraction Procedure (EP) Toxicity Test and Toxicity Characteristic Leaching Procedure
YT30090HW | Millipore ZHE Hazardous Waste System 1/Pack
13899 | ZHE Holder, piston pusher 1/Pack
XX2702512 | 2-way Valve, 1/8 in. NPTM, stainless steel 1/Pack
XX6700010 | Cylinder O-rings 3/Pack
XX6700024 | Vent/Relief Valve, 9 bar 1/Pack
XX6700104 | Street Elbow, 1/4 in. NPTF to M 1/Pack
YT3009001 | Piston with O-rings, wiper seal 1/Pack
YT3009002 | Fitting Luer 1/8 in. NPTF 1/Pack
YT3009003 | Piston O-rings, wiper seal 3/Pack
YT3009013 | Quick-disconnect Female Swagelok 1/Pack
YT3009014 | Quick-disconnect Male Swagelok 1/Pack
YY2209064 | Support Screen 90 mm, stainless steel 1/Pack
YY2209068 | O-ring, 2-235, 90 mm, fluoroelastomer 6/Pack
YY2214257 | Hand Knob 1/Pack
XX6700P05 | Dispensing Pressure Vessel, 5 L 1/Pack
YT3009015 | ZHE Tight Syringe, 50ml 1/Pack
YT3009016 | ZHE Tedlar Bag, 1 liter 10/Pack
XX3002567 | Adapter, 1/8 in. NPTF to M Luer-Lok, chrome plated 1/Pack
XX6700024 | Vent/Relief Valve, 9 bar 1/Pack
XX6700030 | Quick-release Nipple & Coupling, 1/4 in. NPTM 1/Pack
XX6700125 | Hex Nipple, 1/4 in. NPTM 51 mm., stainless steel 1/Pack
XX6702507 | Tube Adapter, 1/4 in. NPTM to 1/4 in. Tube 1/Pack
XX6702508 | Tubing, 6 mm O.D. x 3 m, polypropylene 1/Pack
YT3009013 | Quick-disconnect Female Swagelok 1/Pack
YY1301015 | Pressure Gauge, 0–7 bar 1/Pack
YY2029348 | Ball Valve, 1/4 in. NPTF, stainless steel 1/Pack
Hazardous Waste Filtration System (142 mm)
EPA approved for TCLP
If your waste samples contain non-volatile or semi-volatile substances or metals, use this Hazardous Waste Filtration System for separation, extraction, and filtration. Developed in collaboration with the US Environmental Protection Agency (EPA), the system is designed for the US EPA Extraction Procedure (EP) Toxicity Test and Toxicity Characteristic Leaching Procedure (TCLP). The device separates solid and liquid phases of waste samples for analysis.
Features & Benefits
Contains interior holder with PTFE coating to prevent heavy metal contamination
Allows easy introduction of bulky samples through wide entry port and removable top plate
Disassembles for easy cleaning
Applications
US EPAEP Toxicity Test and Toxicity Characteristic Leaching Procedure
YT30142HW Hazardous Waste Filtration System, 142 mm 1/Pack
YT3014257 | Under drain Support, PTFE-coated 1/Pack
YY2004045 | Clamp 1 1/2 in. TC 1/Pack
YY2004055 | 1 1/2 in. TC sile gasket 1/Pack
YY2214251 | Legs with Caps, 3/16 in. wrench 3/Pack
YY2214252 | Hand wheel Wrench for 142 mm holder 1/Pack
YY2214253 | O-ring, 2-251, PTFE 1/Pack
YY2214257 |Hand Knob 1/Pack
YY2214265|O-ring, 2-251, sile 4/Pack
XX6700035 |Tubing for pressure use, 1/2 in. ID 1/Pack
YY2004057|Gasket, 1-1/2 in., PTFE-coated fluoroelastomer 10/Pack